AC40 Instructions for Use - EN
3.1 Back Panel External Connections – Standard Accessories
The back panel contains all the rest of the main connectors (sockets):
LAN (for
future use)
USB connectors
Power
for printer, PC-
connector
connection &
keyboard
Special notes:
The HLS (hearing loss simulator) connector is currently not used. Use the Standard Headphone
and HF Headphone connectors for HLS. This is prepared for future use.
In addition to the standard DD45 headset, four other air conduction transducers may be used
(they all connect to specific outputs on the AC40):
HDA300: High Frequency requires a HF headset.
CIR33 for insert masking: Insert phone CIR33 for insert masking has a limited sound
quality, making it only adequate for masking noise presentation.
EAR-Tone 3A or 5A general purpose insert phone: Insert headphone EAR-Tone 3A or
5A are high quality transducers that may be used instead of the DD45/TDH39. It
improves cross hearing from the normal approximately 40dB of the TDH39 to
approximately 70dB. Masking as well as avoiding over-masking is thus easier with this
type of headphone.
IP30 insert phone is the standard insert phone with same properties as EAR-Tone 3A
Currently FF3/FF4 (both the powered and non-powered) is not used. This is prepared for future
use.
Assistant Monitor: There is always a direct connection through the goose neck microphone to the
assistant wearing a headset connected to the "Assistant Monitor" output.
The LAN connection is currently not used for any application (only internally in production).
Mic 2: Please refer to the section about Patient Communication (Talk Forward and Talk Back).
When using the HDMI output the output resolution will be the saved as on the build in 8,4 inch
display: 800x600.
CD-input: It is required that any attached CD-player has a linear frequency response in order to
comply with the requirements of IEC 60645-2.
USB connections is used for:
PC connection to Diagnostic Suite (the large USB connector)
Direct print
PC-keyboard (for entering client names)

3.2 PC-Interface

Please refer to the Diagnostic Suite operation manual regarding hybrid mode (on-line and PC-operated
mode) as well as patient/session data transfer.
Amplified
Free Field
High Freq.
outputs
Left / Right
(2x20
HDMI output
Free Field 1
for external
and 2
monitor (e.g.
(external
for patient
amplificatio
counceling)
n needed)
Response
Switch 1 / 2
Insert
Bone conductor
masking
B81 /B81
1 / 2
Standard
Standard
Headphone
Insert Phone
s
EarTone 3A
DD45/TDH3
/ IP30
9/HDA300
Page
Patient
Assistant
Monitor
Control
output
Extra Talk
For Talk
forward
Back
mic., e.g.
Speaker
for table
mic.
8
External
CD / MP3
input