Mitsubishi FX-20P-E Operation Manual page 87

Handy programming panel
Table of Contents

Advertisement

FX-20P-E Handy programming panel
Example:Changing the set value from the device monitor
Changing the set value of the T5 from "K100" to "K200"
Display example
In the step 1)
M
T 5
P
R
In the step 4)
T
T 5
P
R
In the step 5)
T
T 5
P
R
• If the set value of a timer (T) is indirectly specified through a data register, the data register
(D) No. can be changed by the operation above.
When changing the present value of a data register (D) which indicates the actual set time,
execute the present value change operation. (Refer to 9.3.)
Key operation
1)
Device monitor
K 0
of the T5
K 100
2)
MNT/TEST
3)
S'P
K 0
K 100
4)
S'P
5)
K
2 0
Prompt
6)
GO
K 0
K
200
The step 3) displays the prompt in the present value of the T5.
The step 4) displays the prompt in the set value of the T5.
0
Test 9
9-7