Mitsubishi F930GOT-BWD-E Hardware Manual

Advertisement

Quick Links

We appreciate it very much that you have purchased our GOT (graphic operation terminal).
Please read the manual of the programmable controller (PLC) main body and the F930GOT Users
Manual together with this manual, sufficiently understand the specifications of the F930GOT, then
correctly use the F930GOT.
Please see to it that this manual is delivered to the end user.
Cautions on Safety
(Make sure to read this paragraph before using the F930GOT.)
Thoroughly read this manual and all documents offered together with the PLC connected to the F930GOT
and other related units before installing, operating and inspecting/maintaining the F930GOT, and correctly
use the F930GOT.
Sufficiently learn all of the knowledge of the units, the information on safety and cautions.
In this manual, cautions on safety are classified into two levels, "DANGER" and "CAUTION".
If the unit is incorrectly handled, the situation may become dangerous and the possibility of death
or serious injury is postulated.
If the unit is incorrectly handled, the situation may become dangerous, the possibility of medium or
slight injury is postulated, and generation of only physical damages is postulated.
Even an item classified as "CAUTION" may lead to a serious result depending on the situation.
Make sure to observe the contents classified into both "DANGER" and "CAUTION".
Make sure that instruction manuals offered together with the units are securely stored so that they can be
referred to at any time upon necessity, and that they are delivered to the end user.
Cautions on design
If a communication error (including disconnection of a cable) occurs while the F930GOT is
monitoring the operation status, communication between the F930GOT and the CPU in the PLC is
aborted and the F930GOT is disabled.
When constructing a system including the F930GOT, make sure that switches which actuate
significant operations in the system are provided in any unit other than the F930GOT so that a
communication error in the F930GOT does not cause problems. If such switches are provided in
the F930GOT, accidents may be caused by erroneous output or malfunction.
Never put control cables and communication cables near the main circuit.
Never bind such cables together with power cables. Keep such cables off the main circuit and
power cables by 100 mm or more. Otherwise, noise may cause malfunction.
Make sure to use your hand to press touch switches on the screen. If an excessive force is
applied on touch switches or a hard or sharp object is used to press them, malfunction may be
caused.
1. Introduction
The F930GOT comes supplied with the following manuals.
F930GOT Hardware Manual (this manual)
Describes the outline, installation, wiring, specifications, etc. of the F930GOT.
F930GOT Users Manual (separate manual)
Describes the operating procedures, the display function, etc. of the F930GOT.
FX-PCS-DU/WIN-E Operation Manual (separate manual)
Describes the operating procedures of the software to create screens.
SWoD5C-GOTR-PACK-E Operation Manual
Describes the operating procedures of the software to create screens. (Refer to the HELP file of the
software.)
F930GOT-BWD-E
HARDWARE MANUAL
[Main Body Instruction Manual]
JY992D83301A

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi F930GOT-BWD-E

  • Page 1 F930GOT-BWD-E HARDWARE MANUAL [Main Body Instruction Manual] JY992D83301A We appreciate it very much that you have purchased our GOT (graphic operation terminal). Please read the manual of the programmable controller (PLC) main body and the F930GOT Users Manual together with this manual, sufficiently understand the specifications of the F930GOT, then correctly use the F930GOT.
  • Page 2: Component Names

    2. Outline The F930GOT is designed to be mounted on the outside surface of a control or operation panel and connected to the programming port of an FX or A Series PLC (excluding A0J2 PLC) housed inside the panel. FX or A The F930GOT can be directly connected to the CPU, a PLC other than Series PC in the MELSEC Series or a micro computer board by means of a...
  • Page 3: Cautions On Installation

    5. Installation Cautions on installation • Do not mount the F930GOT in an environment that contains dust, soot corrosive or conducive dust, corrosive or flammable gas, or expose the unit to high temperatures, dew condensation, rain and wind or impact and vibration. If the F930GOT is used in such a place, electrical shock, fire, malfunction, damages or deterioration may be caused.
  • Page 4: Maintenance

    • Never disassemble or modify the F930GOT. Disassembly or modification may cause failure, malfunction or fire. * For repair, contact Mitsubishi Electric System Service. • Make sure to turn off the power, then connect/disconnect cables. If you connect/disconnect cables while the power is turned on, failure or malfunction may be caused.
  • Page 5: Specifications

    For approximately one month after the control device for battery voltage drop turns ON, the battery backs up the alarm history and the current time. When the control device turns ON, replace the battery soon. Product name •Battery FX  -32BL Replacement procedure 1) Turn off the power of the F930GOT and, remove the battery...
  • Page 6 If in doubt at any stage during the installation of the F930GOT always consult a professional electrical engineer who is qualified and trained to the local and national standards. If in doubt about the operation or use of the F930GOT please consult the nearest Mitsubishi Electric distributor.
  • Page 7 FX or A Series PLC (excluding A0J2 PLC) housed inside the panel. FX or A F930GOT-BWD-E dust, corrosive or flammable gas, or expose the unit to high temperatures, dew condensation, The F930GOT can be directly connected to the CPU, a PLC other than Series PC rain and wind or impact and vibration.
  • Page 8 If the battery is handled in such a way, bursting or fire may be caused. electrical engineer who is qualified and trained to the local and national standards. If in doubt about the operation or use of the F930GOT please consult the nearest Mitsubishi Electric •...