File Register; Run Input - Mitsubishi FX-20P-E Operation Manual

Handy programming panel
Table of Contents

Advertisement

FX-20P-E Handy programming panel
10.5.6

File register

• Set the number of blocks of the memory to be assigned to file registers. Up to 500 file
registers are available in each block. Out of the preset memory capacity, 500 steps is used
by each block.
• The allowable setting range in each PLC is as shown below.
FX
/FX
0
0S
FX
/FX
1S
0N
FX/FX
Series PLC
2C
FX
/FX
1N
2N
Display example
FILE REGISTER
0 BLOCK
(ONE BLOCK = 500)
10.5.7

RUN INPUT

• In the FX
1S
assigned as the RUN terminal.
Display example
RUN INPUT
USE
X000
DON'T USE
Series PLC
Series PLC
/FX
Series PLC
2NC
- In the allowable setting range shown above, input the
number of required blocks, then press the [GO] key.
/FX
/FX
/FX
Series PLC, general-purpose inputs X000 to X017 can be
2N
1N
2NC
- When using a general-purpose input as the RUN terminal,
place the cursor on "USE", enter the input No. (0 to 17), then
press the [GO] key.
- When not using a general-purpose input as the RUN
terminal, place the cursor on "DON'T USE", then press the
[GO] key.
: File registers are not available. Set "0".
: 0 to 3 blocks
: 0 to 4 blocks
: 0 to 14 blocks
Others Function 10
10-16