Focus-Positioning Of The Scanner And 2Nd/3Rd Mirrors Carriage - Minolta Di200 Service Manual

Hide thumbs Also See for Di200:
Table of Contents

Advertisement

FrameMaker Ver.5.5E(PC) Di200/Di251/Di351 DIS/REASSEMBLY, ADJUSTMENT
01.02.09
3-6.
FOCUS-POSITIONING OF THE SCANNER AND 2ND/3RD
MIRRORS CARRIAGE
Make this adjustment after any of the following procedures has been performed:
• After the Scanner Drive Cables have been replaced.
• When the Scanner has been removed.
• When the Scanner Drive Cable comes unwound.
Requirement
• With the Scanner fixed to the Scanner Drive Cables, there should be no gap between the
Scanner/Mirrors Carriage Positioning Jig and the Scanner and also between the Scan-
ner/Mirrors Carriage Positioning Jig and the 2nd/3rd Mirrors Carriage.
Adjustment Procedure
4011D084AA
4011D085AA
4. Press the 2nd/3rd Mirrors Carriage up against the jigs and make sure that there is no
clearance at the front and rear ends.
5. Press the Scanner tightly up against the jigs and, keeping that condition, tighten the
setscrews of the cable holding plate.
Scanner/Mirrors
Carriage Positioning
Jig
2nd/3rd Mirrors
Carriage
1. Remove the Exposure Lamp.
See steps 1 through 7 of "(8) Removal of the Scan-
ner" of "2-5. OPTICAL SECTION.
2. Temporarily loosen the set screws of the cable
holding plate of the Scanner Drive Cable.
3. Fit the Scanner/Mirrors Carriage Positioning Jigs
in the space between the Scanner and 2nd/3rd
Mirrors Carriage
Front
Rear
D-55
Scanner
Scanner/Mirrors
Carriage Positioning
Jig
4011D086AB

Advertisement