01.01.17
Code
Description
C0B38 Shift Motor drive mal-
function
C0B48 Exit Roller/Rolls Spacing
Motor drive malfunction
C0B4A Storage Roller/Rolls
Spacing Motor drive mal-
function
C0B4D Paper Holding Tray Motor
drive malfunction
C0B4E Finisher Tray Motor drive
malfunction
C0B50 Stapling Motor 1 drive
malfunction / Stapling
Motor drive malfunction
C0B54 Stapling Motor 2 drive
malfunction
C0B73 Punch Motor drive mal-
function
C0B78 Hole Position Selector
Motor drive malfunction
(U.S.A. and Canada)
C0B80 Shift Motor drive mal-
function
C0BA0 Elevator Motor drive mal-
function
C0F32 Faulty ATDC Sensor
C0F33 ATDC adjustment failure • In an F8 (ATDC control voltage automatic adjust-
C1038 Engine connection error
Detection Timing
See the relevant option service manual.
The value of data read by the ATDC Sensor is faulty.
(ATDC Sensor reading is 19 % or more, or 7 % or
less.)
ment) operation, the adjustment of ATDC control
voltage is not completed within 1 min. after the
ATDC Sensor sampling.
• In an F8 operation, the control voltage falls outside
the range of 5.39 V to 8.15 V.
• The system fails in checking initial engine connec-
tion when the Power Switch is turned ON.
• The system succeeded in checking initial connec-
tion when the Power Switch was turned ON; then it
fails in rechecking initial connection through the exe-
cution of a software reset when a communications
error occurs during operation.