FrameMaker Ver.5.5E(PC) Di200/Di251/Di351 DIS/REASSEMBLY, ADJUSTMENT
01.02.09
3. Call the Adjust Mode to the screen.
4. Touch "IR" , "Zoom Adjust", and "CD", in that order.
5. Press the Clear key to clear the current setting value.
6. Enter the new setting value from the 10-Key Pad.
Setting Instructions
If the scale on the copy is longer than the actual scale, decrease the setting value.
If the scale on the copy is shorter than the actual scale, increase the setting value.
If the measurement does not fall within the specifications through one setting, try another
setting.
4011P300CA
Setting Value
7. Touch "END" to validate the setting value.
NOTE
• Be sure to touch "END" to return to the normal operating mode. If the Panel Reset key is
used, the previous setting remains valid.
Use to enter setting value.
D-50
Use to clear
setting value.
1167D069AA