Advertisement

vacon • 29
5.3
Telegrams implemented by Vacon
5.3.1

Telegram building blocks

5.3.1.1
STW1 - Control Word 1
Table 36. Overview of the assignment of the bits of control word 1
Bit
0
ON
1
No Coast Stop (no OFF2 )
2
No Quick Stop (no OFF3)
3
Enable Operation
4
Enable Ramp Generator
5
Unfreeze Ramp Generato
6
Enable Setpoint
7
8
9
10
Control by PLC
11
Device-specific
12-15
Device-specific
5
Significance
Speed control mode
Bit value is 1
Fault Acknowledge (0 -> 1)
Not used
Not used
®
100
Bit value is 0
OFF
Coast Stop (OFF2)
Quick Stop (OFF3)
Disable Operation
Reset Ramp Generator
Freeze Ramp Generator
Disable Set Point
No control by PLC
Device-specific
Device-specific