1. INTRODUCTION
The Trianco Eurotrader Boiler has been designed to
conform to European Directive/Standards BED 92/42
EEC LVD EN 60335-1 EMC 89/336/EEC.
The matched pressure jet burner which is exceptionally
quiet in operation, ensures clean and efficient
combustion with low NO x emissions
The Eurotrader boiler is suitable for installation in a
garage.
The Eurotrader boilers are suitable for all normal open
vented central heating and indirect hot water systems
and can also be used with sealed systems up to a
working pressure of 3 bar with the appropriate sealed
system safety equipment.
Two flow and return sockets are provided to facilitate
connection to the heating and hot water systems.
Due to high efficiency of this range of boilers; it is recom-
mended that they are filled on fully pumped system using
diagonally opposite connections of the heat exchanger
The boiler is fully automatic in operation and incorporate
all necessary safety controls to ensure safe and reliable
operation.
Trianco EuroStar boilers are supplied with the burner set
for Kerosene 28 sec. Class C fuel to meet the Building
Regulation requirements for low level flue discharge. It is
recommended this fuel is also used when the boiler is
connected to a conventional chimney because of the
clean burning characteristics of Kerosene.
To comply with regulations in force, your new boiler must be installed and commissioned
by an OFTEC-registered engineer. The installation must also comply with current
Failure to meet the terms of these requirements may invalidate your guarantee.
THE PERSON(S) WHO INSTALLS THIS APPLIANCE, COMMISSIONS, SERVICES OR
CARRIES OUT ANY REMEDIAL WORK, IE ELECTRICAL FAULT FINDING, MUST
HAVE SUITABLE ENGINEERING QUALIFICATIONS
Please note: It is essential in the interest of boiler effi-
ciency and reliable performance that once the boiler has
been installed it is first commissioned, preferably by an
OFTEC registered engineer.
It is the responsibility of the installer to ensure that the
boiler is commissioned.
Always switch off the electrical supply before removing
any of the covers for cleaning.
If any part of the boiler or its flue is modified, then the
guarantee/warranty will be invalidated.
We recommend that you keep these instructions in a
place near your appliance for easy reference.
Balanced Flue Kits
The boilers are supplied suitably equipped for connection
to a conventional chimney, but can readily be converted
into a room-sealed balanced flue appliance by using a
Trianco balanced flue kit. These kits allow the boiler to be
installed in a wide variety of site conditions, from low-level
discharge through the wall, to high-level discharge (see
balanced flue kit details - section 3 ).
Two distinct styles of flue kit are available. The circular
balanced flue kit is available in both low-level horizontal
and vertical set-ups. The square balanced flue kit is
available in a low-level horizontal format and a high-level
horizontal format (in conjunction with a circular vertical
adaptor kit).
Note:
Both the square and circular low level horizontal
balanced flue kits can be used for left-hand, right-
hand, and rear exhaust.
Important Notice:
Building Regulations, Part L.
4