2.2) Operating media-Coolant

Conventional
coolant
Application
Mixture

2.3) Operating media-Fuel

Antiknock
properties
Page 2-6
December 01 2017
Obey the latest edition of Service Instruction SI-915 i-001, for
the selection of the correct coolant.
Conventional coolant mixed with water has the advantage of a
higher specific thermal capacity than water-less coolant.
When correctly applied, there is sufficient protection against va-
por bubble formation, freezing or thickening of the coolant with-
in the operating limits.
Use the coolant specified in the manufacturers documentation.
Obey the operating media manufacturer's instructions!
Obey the latest edition of Service Instruction SI-915 i-001, for
the selection of the correct fuel.
Use only fuel suitable for the respective climatic zone.
NOTE
Risk of vapour formation if using winter fuel for summer
operation.
Fuels with following specification can be used:
Anti knock properties
NOTE
For fuels according to ASTM D4814 specifications following
AKI (Anti Knock Index) value has to be observed: min. AKI 91.
BRP-Rotax
ATTENTION
ATTENTION
ATTENTION
ATTENTION
Usage/Description
915 iSc/iS
Min. RON 95
Effectivity: 915 i A Series
Edition 0 / Rev. 0