3.4) After engine start

Warming up
period
Page 3-10
December 01 2017
Non-compliance can result in serious injuries or death!
Do not start the engine if any person is near the engine.
Step
Step Description
1
Check engine instru-
ments (Warning Indi-
cators and
Operational Limits)
and ensure compli-
ance with the operat-
ing limits while step 2
to 4.
Example
(Symbolic)
2
Set Throttle Valve as
required.
Example
(Symbolic)
3
Set Throttle Valve as
required.
Example
(Symbolic)
4
Reduce Throttle
Valve as required.
Example
(Symbolic)
BRP-Rotax
m WARNING
Procedure
HIC A: If a 12 V voltage drop
between Terminal 2 and Termi-
nal 8 (permanent or oscillating)
is detected, shut OFF engine
and perform troubleshooting.
HIC B: If a 12 V voltage drop
between Terminal 2 and Termi-
nal 10 (permanent or oscillat-
ing) is detected, shut OFF
engine and perform
troubleshooting.
Display CAN A/B: Check and
ensure compliance with opera-
tional limits.
Warning Lamp A: Check
Warning Lamp B: Check
Pilot Display: Check
Set linearized throttle position
in away that the engine runs on
approx. 2000 rpm for approx. 2
minutes.
Set Throttle
Set linearized throttle position
in a way that the engine runs on
approx. 2500 rpm until oil tem-
perature reaches 50 °C (120 °
F).
Set Throttle
Set linearized throttle position
so that the engine runs on idle.
Reduce Throttle
Effectivity: 915 i A Series
Edition 0 / Rev. 0