3.6) Engine shut-off

Effectivity: 915 i A Series
Edition 0 / Rev. 0
Step
Step Description
Example (Symbolic)
NOTE
Cycling the propeller governor puts a relatively high load on the
engine. Unnecessary cycling should be avoided.
Step
Step Description
1
Check the engine in-
struments (Warning
Indicators and Op-
erational Limits) and
ensure compliance
with the operating
limits while step 2 to
5.
Example (Symbolic)
2
Reduce Throttle
valve as required.
Example (Symbolic)
3
Await cooling down
phase.
4
Deactivate ECU
Example (Symbolic)
BRP-Rotax
Procedure
Fuel pump 2: OFF
Procedure
HIC A: If a 12 V voltage drop
between Terminal 2 and Termi-
nal 8 (permanent or oscillating)
is detected, shut OFF engine
and perform troubleshooting.
HIC B: If a 12 V voltage drop
between Terminal 2 and Termi-
nal 10 (permanent or oscillat-
ing) is detected, shut OFF
engine and perform
troubleshooting.
Display CAN A/B: Check and
ensure compliance with opera-
tional limits
Warning Lamp A: Check
Warning Lamp B: Check
Pilot Display: Check
Set linearized throttle position
so that the engine runs on idle.
Reduce Throttle
Wait > 2 minutes
HIC A: Disconnect Terminal 1
and Terminal 7 to turn OFF
ECU Lane A
HIC B: Disconnect Terminal 1
and Terminal 9 to turn OFF
ECU Lane B
Lane select Switch A: OFF
Lane select Switch B: OFF