SETUP AND CALIBRATION, CONT.
Dual-Point with Zero (First Zero) Calibration
IMPORTANT! The functions of numeric keys are replaced by using the
UNITS/
LEFT ARROW
identified by the blinking character and can be advanced to the left to the next
position by pressing the UNITS/
key will change the blinking character to the next value.
ARROW
! > – First Calibration Weight
The display will show ! > . This is the first of two calibration weights. This weight
could be ZERO (NO LOAD) or the TEST WEIGHTS / TEST LOAD.
If the first calibration weight is to be ZERO (NO LOAD), press the TARE/
If the first calibration weight is to be the TEST WEIGHTS / TEST LOAD, use the
UNITS/
LEFT ARROW
test weights. NOTE! When entering values for ! >, the digits start displaying on
the right side of the display and proceed to the left. When large values are used (more
than 3 digits), the ! > prompt will automatically scroll off the left side of the display
to show the additional digits on the right as they are entered.
Place the weights on the scale platform, then press the TARE/
Starting at the left and proceeding right, a series of dashes will appear on the display.
The dashes will stay on the display momentarily, then disappear, after which the display
will show: !>.
!> - Second Calibration Weight
The display will show !> . This is the second of two calibration weights. This
weight could be ZERO (NO LOAD) or the TEST WEIGHTS / TEST LOAD.
If the second calibration weight is to be ZERO (NO LOAD), press the TARE/
If the second calibration weight is to be the TEST WEIGHTS / TEST LOAD, use the
UNITS/
LEFT ARROW
test weights. NOTE! When entering values for !>, the digits start displaying on
the right side of the display and proceed to the left. When large values are used (more
than 3 digits), the !> prompt will automatically scroll off the left side of the display
to show the additional digits on the right as they are entered.
Place the weights on the scale platform, then press the TARE/
Starting at the left and proceeding right, a series of dashes will appear on the display.
The dashes will stay on the display momentarily, then disappear, after which the display
will show: !>.
!> - Last Calibration Weight
The display will show !> . This weight is not used. Press the TARE/
skip !> and advance to *-6.
8200-M024-O1 Rev G y 205 Installation & Technical
and the ASTERISK/
LEFT ARROW
and ASTERISK/
UP ARROW
and ASTERISK/
UP ARROW
keys. The cursor location is
UP ARROW
key. Pressing the ASTERISK/
keys to input the value of the calibrated
key.
ENTER
keys to input the value of the calibrated
key.
ENTER
ENTER
UP
key.
ENTER
key.
ENTER
key to
23