SETUP AND CALIBRATION, CONT.
`@`3 (`@`3) - Analog to Digital Filtering
3!;> (Digital Filtering)
With `@`3`(`@`3) displayed, press the TARE/
3!;>. Press the TARE/
acceptable, press the TARE/
key to toggle to a new setting and then press the TARE/
values are: 0, 1, 2 or 3. Note, that if you select 3 (Custom Filtering) two additional prompts will
be displayed.
3!;>`
0
Disabled – NO Filtering
1
MINIMAL FILTERING (sample rate = 2)
2
MODERATE FILTERING (sample rate = 1)
3
CUSTOM FILTERING
NOTE! The prompts, > (Filter Level) and 2> (Break Range) will only be displayed if you
selected 3 (Custom Filtering) for the 3!;> (Digital Filtering) prompt.
>`(Filter Level)
Press the TARE/
ENTER
a number from 1 to 99 that corresponds to the level of filtering with 99 being the greatest
filtering and 1 the least. To accept the value displayed, press the TARE/
otherwise, use the ASTERISK/
TARE/
key to save it.
ENTER
2> (Break Range)
Press the TARE/
ENTER
range is a number from 1 to 255 that corresponds to the number of division change to
break out of the filtering. Press the TARE/
the ASTERISK/
UP ARROW
key to save it. Note that selecting 0 disables this feature.
*9> (Sample Rate)
Press the TARE/
ENTER
displayed is the sample rate in samples per second. Press the TARE/
the displayed value or use the ASTERISK/
100) and then press the TARE/
'0*> (Motion Range)
Press the TARE/
ENTER
displayed value is acceptable, press the TARE/
ASTERISK/
key to toggle to a new range (the number of divisions of change
UP ARROW
permitted before indicating unstable) and then press the TARE/
setting. Allowable range values are: 0 through 99 divisions.
*> (Stable Count)
Press the TARE/
ENTER
weight readings before indicating stable weight. This helps filter weight readings for stability
when trying to capture stable weight. If the displayed value is acceptable, press the
TARE/
key to save it. Otherwise, use the ASTERISK/
ENTER
value and press the TARE/
count are: 3 through 255.
8200-M024-O1 Rev G y 205 Installation & Technical
20
key to show the current value. If the setting displayed is
ENTER
key to save it. Otherwise, use the ASTERISK/
ENTER
key to show the current setting for the filter level. The filter level is
key to toggle to a new setting and then press the
UP ARROW
key to show the current setting for the break range. The break
ENTER
key to toggle to a new setting and then press the TARE/
key to show the current setting for the sample rate. The value
UP ARROW
key to save it.
ENTER
key to view the current setting for the range of motion detection. If the
ENTER
key to view the current setting for the number of consecutive stable
key to save the new setting. Allowable values for the stable
ENTER
key. The display will change to
ENTER
key to save it. Allowable
ENTER
key to keep the displayed value or use
ENTER
key to toggle to a new value (1 to
key to save it. Otherwise, use the
key to save the new
ENTER
key to toggle to a new
UP ARROW
UP ARROW
key,
ENTER
ENTER
key to save