System Identification - Redline RDL-3000 User Manual

Advanced broadband wireless infrastructure solutions
Hide thumbs Also See for RDL-3000:
Table of Contents

Advertisement

RDL-3000

System Identification

System Name: Enter the name for this RDL-3000. The system name may be up to thirty
alpha-numeric characters including a-z, A-Z, 0-9, dash (-), and underscore (_).
System Details: Enter additional descriptive details about this RDL-3000. The system
details may be up to thirty alpha-numeric characters including a-z, A-Z, 0-9, dash (-), and
underscore (_).
System Location: Enter additional descriptive details about this RDL-3000. The system
location information may be up to thirty alphanumeric characters including a-z, A-Z, 0-9,
dash (-), and underscore (_).
Contact: Enter additional descriptive details about this RDL-3000. The contact
information may be up to thirty alpha-numeric characters including a-z, A-Z, 0-9, dash (-
), and underscore (_).
Basic Ethernet Configuration
IP Address: Enter the IP address for this RDL-3000. The IP address is routable both
through the Ethernet port and over the wireless interface.
IP Subnet Mask: Enter the IP subnet mask.
Default Gateway Address: Enter the IP address of the default gateway or router on the
Ethernet segment connected to the RDL-3000 Ethernet port.
Advanced Ethernet Configuration
Ethernet Mode: Select the operating mode of the Ethernet port.
Auto - Automatically negotiate the connection speed and duplex.
10Mbps HD - Operate at 10Base-T half-duplex only.
10Mbps FD - Operate at 10Base-T full duplex only.
100Mbps HD -.Operate at 100Base-T half-duplex only.
100Mbps FD - Operate at 100Base-T full duplex only.
Important:
communicating Ethernet devices are configured for auto-negotiate. The auto-negotiate
feature does not detect the speed and duplex of Ethernet equipment operating at a
fixed speed and duplex. Duplex mismatches may result in an unexpected loss of
communications. It is recommended to set the Ethernet ports to operate at a fixed
speed of 100Base-T using full duplex.
SNTP Enable: Check this box
allows RDL-3000 systems to time-stamp log messages using a network time server.
When enabled, you must enter the network address of the SNTP server in the SNTP
Server IP Address field.
When SNTP is enabled, the following additional configuration fields are visible:
SNTP Server IP Address: Enter the network address of the SNTP server.
SNTP Polling Interval [hours]: Enter the SNTP polling interval (hours).
Time Zone (GMT) [hh:mm]: Enter the hours offset from GMT for this time zone.
Syslog Enable: Check this box
allows RDL-3000 log messages to be saved in a central repository. When enabled, you
must enter the network address of the Syslog server in the Syslog Server IP Address
field. When Syslog is enabled, the following additional configuration field is visible:
Syslog Server IP Address: Enter the network address of the Syslog server.
HTTP Enable: Check this box
70-00158-01-DRAFT
User Manual
The
auto-negotiate
to enable the SNTP protocol support. This feature
to enable the Syslog protocol support. This feature
to enable the HTTP (Web) interface.
Proprietary Redline Communications © 2010
function
works
correctly
Page
only
when
both
58
of 142
November 25, 2010

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents