Non-Continuous Test - Matco Tools FixAdvisor MD70 Operating Instruction

Table of Contents

Advertisement

Additional Tests

NON-CONTINUOUS TEST

"Bank One" indicates the side of the engine where cylinder
number one is located (V0type engines). Bank Two is opposite
of Bank One.
Y or YY - These characters identify the location of the O2 sensor in
relation to the exhaust system catalyst. An O2 sensor located upstream
of the catalyst is identified by the designation "1" or "S1", a sensor lo-
cated downstream of the Catalytic Converter is identified as "2" or "S2."
For example, O2S12 or O2SB1S2 is the designation for the
downstream O2 sensor for cylinder bank 1.
The FixAdvisor does not perform O2 sensor tests, but retrieves
results from the most recently performed O2 sensor tests from the
on-board computer's memory. You may retrieve O2 sensor test
results for only one test of one sensor at any given time.
1. From the "Special Test Menu", use the UP
and DOWN
to highlight O2 Sensor Test then press the
ENTER
2. A
"One
displays while the request is sent to the
vehicle's on-board computer.
The "Select Sensor" screen displays.
The screen shows all O2 sensors
applicable to the vehicle under test.
If O2 sensor tests are not supported
by the vehicle under test, an advisory
message shows on the FixAdvisor's
display. Press the M button to return
to the "Special Test Menu."
3. Use the UP
as necessary, to highlight the O2 sensor
for which you wish to view test results,
then press the ENTER
4. When test results have been retrieved,
data for the selected sensor test will show
on the FixAdvisor's display.
5. When you have finished viewing the
retrieved test data, press the M button to
return to the "Select Sensor" screen.
NON-CONTINUOUS TEST
The Non-Continuous Test function retrieves and displays test results
for O2 sensor test, emission-related powertrain components, and
systems that are not continuously monitored. The tests available are
determined by the vehicle manufacturer.
The FixAdvisor does not perform non-continuous test, but
retrieves results from the most recently performed tests from
the on-board computer's memory. You may retrieve non-
continuous test results for only one test at any given time.