Option 78 — Data Terminal Ready (DTR)
Interface line pin 20 can be made true when the printer status is:
ONLINE AND BUFFER ALMOST EMPTY (READY)
OFFLINE OR BUFFER ALMOST FULL (BUSY)
In addition, the DTR interface line can be held always ON (true) or always
OFF (false).
Option
Number
.0
.1
.2
.3
Interfaces
Display
Configuration
Description
Enable ON condition when printer is online and buffer is not full
78.0
(Ready) (default).
Enable ON condition when printer is offline or buffer is full (Busy).
78.1
Enable always ON.
78.2
Enable always OFF.
78.3
8–23