Electrical, Physical, Environmental and Product Certification
Specifications
Electrical*
Voltage
Frequency
Input Voltage
Current (rms)
Power Factor
120/240 Vac
Physical
Height
Depth
Width
Weight
Shipping
Environmental
Operating
Storage
Acoustic Noise
Product Certification
UL
FCC
C–6
North American
120 (+10%, –30%) Vac single phase
47 to 62 Hz.
120 Vac nominal
4 amps maximum
0.65 nominal
Factory installed for 120 Vac or 240
Vac operation; power consumption
same as international model.
*The electrical specifications apply to all three printers in the MVP–Series.
MVP, 150B
10.5 in.
20.7 inches
24.6 inches
60 lbs
31.69 in. wide; 28.19 in. deep;
17.38 in. high; 75 lbs.
Temperature
0 to 40 degrees C.
– 40 to +70 degrees C.
60 dBa maximum on Printronix pedestal
UL Standard 478 Listing.
FCC Rules, PartI5, Docket 20780–Part A Compliance.
Characteristics/Function
International
120 (+10%, –30%) Vac or
240 (+10%, –30%) Vac single phase
47 to 62 Hz.
120 Vac nominal; 240 Vac Nominal
4 amps maximum; 2 amps maximum
0.65 nominal; 0.65 nominal
L150
11.5 in.
20.7 inches
24.6 inches
70 lbs
29.7 in. wide; 26.3 in. deep;
16.1 in. high; 90 lbs.
Humidity
10% to 90% rh noncondensing
5% to 95% rh noncondensing