Appliance Data - Valor 719 Installer's Manual

Inset live fuel effect gas fire
Hide thumbs Also See for 719:
Table of Contents

Advertisement

This product uses fuel effect pieces and a burner compartment rear wall
containing Refractory Ceramic Fibres (RCF), which are man-made vitreous
silicate fibres. Excessive exposure to these materials may cause irritation to eyes,
skin and respiratory tract. Consequently, it is important to take care when
handling these articles to ensure that the release of dust is kept to a minimum. To
ensure that the release of fibres from these RCF articles is kept to a minimum,
during installation and servicing we recommend that you use a HEPA filtered
vacuum to remove any dust and soot accumulated in and around the fire before
and after working on the fire. When replacing these articles we recommend that
the replaced items are not broken up, but are sealed within a heavy duty polythene
bag, clearly labelled as RCF waste. This is not classified as "hazardous waste" and
may be disposed of at a tipping site licensed for the disposal of industrial waste.
Protective clothing is not required when handling these articles, but we recommend
you follow the normal hygiene rules of not smoking, eating or drinking in the work
area and always wash your hands before eating or drinking.
This appliance does not contain any component manufactured from asbestos or
asbestos related products.
Gas
Inlet Pressure
Input - Max. (Gross)
Input - Min. (Gross)
Inlet Test Pressure (Cold)
Gas Connection
Burner Injector
Pilot & Atmosphere Sensing
Device
Ignition
Aeration
* When converted using Kit 0595221
The appliance data label is located on a plate at the base of the fire. This can be seen by
removing the lower frefront casting.
INSTALLER GUIDE

2. APPLIANCE DATA

Natural (G20)
20mbar
6.0kW (20,500Btu/h)
2.7kW (9,212Btu/h)
20.0 ± 1.0mbar (8.0 ± 0.4in
w.g.)
8mm pipe
Stereomatic Cat 82 - 069
Copreci Ref. O.D.S
21500/166
Electronic
(Battery 9V PP3)
See section 17.1
Page 5
Propane (G31) *
37mbar
6.1kW (20,800Btu/h)
4.3kW (14,670Btu/h)
37.0 ± 1.0 mbar (14.85 ±
0.4in w.g.)
8mm pipe
Stereomatic Size 128
Copreci Ref. O.D.S
21500/166 Fitted with RBM
180 - 02 injector
Electronic
(Battery 9V PP3)
Non-adjustable