6. For concealed connection only: Pierce a
hole in the seal at the back of the
convection box. See figure 13. The seal
must envelop the pipe. If the hole is larger
than the pipe, seal it with tape. Do not
pierce the seal unless the supply pipe is to
pass through it.
7. Fit the upper case support strip to the
top of the convection box, using three
screws inserted from the back of the
appliance. See figure
14.
8. Colourway only
Detach the slider
knob by removing
and discarding two
screws. Attach the
slider knob extension
bracket to the slider
arm using two of the
screws supplied in the
bag containing the extension bracket. Attach the slider
knob to the slider extension bracket using the other
two screws supplied in the bag containing the
extension bracket. See figure
15.
9. There is a length of self
adhesive foam seal supplied
with the fire. This will need to
be fitted to the outer rear edges
of the side and top flanges of
the convector box. Cut the
foam seal to the required
length. Be careful not to stretch
the seal when measuring.
Remove the protective backing
from the foam seal and fit this
to the rear of the top flange
(See figure 16).
INSTALLER GUIDE
Figure 14. Upper case support
Figure 16. Fitting the foam seal
Page 18
Figure 13. Concealed connection seal
piercing
Figure 15. Colourway slider
knob assembly