Ignition Check - Valor 719 Installer's Manual

Inset live fuel effect gas fire
Hide thumbs Also See for 719:
Table of Contents

Advertisement

possible, upstairs rooms and loft spaces for signs of escaping smoke indicating a
defective flue. If there is not a definite flow warm the flue for a few minutes and repeat
the smoke pellet test. If there is still no definite flow the flue may need remedial work –
Do not fit the appliance until there is a definite flow through the flue.
Before attempting to install, it is worth checking that the electronic ignition system
performs satisfactorily.
Fit the battery to the ignition block located below the burner tray at the left side (see
figure 7). The positive terminal (+) is to the top as you insert.
Depress the slider control as far as it will go. This should close the ignition circuit.
!
Sparks should be seen tracking from the electrode pin to the pilot tip. See figure 8.
If there are no sparks make the following checks.
!
Check condition of battery and that it is correctly
!
fitted.
If the above is satisfactory, check the ignition circuit
!
and components - see the servicing section in this
manual.
INSTALLER GUIDE

6. IGNITION CHECK

Page 15
Figure 7. Fitting Battery
Figure 8. Slider control