Maintenance
CLEANING AND STORAGE
1. The meter should be cleaned with a damp cloth and mild detergent when necessary. Do not use
solvents or abrasives.
2. Store the meter in an area with moderate temperature and humidity.
Specifications
Function
CO
2
Temperature
Humidity
Display
Sensor Type
Response
Datalogging
Sample rate
Operating Conditions
Storage Conditions
Power Supply
Dimensions / Weight
www.ponpe.com
Range
Resolution
0 to 9999ppm
1ppm
-10 to 60°C
0.1°
14 to 140°F
0.1 to 99.9%
0.1%
LCD
CO
: NDIR (non-dispersive infrared) technology
2
Humidity: Capacitance sensor;
Temperature (air): Thermistor
CO
: <2min for 90% step change
2
Temp: <2min for 90% step change
%RH: <10min for 90% step change
Up to 15999 points
1 second to 4 hours-59 minutes-59 seconds
-10 to 60°C (14 to 140°F); < 90% RH non-condensing
-20 to 60°C (-4 to 140°F); <99% RH non-condensing
5VDC (±10%), ≥ 500mA (AC adaptor supplied)
117x102x102mm (4.6x4x4"); 204g (7.2 oz.)
Accuracy
±(5%rdg +50ppm)
±0.6°C/0.9°F
±3%(10 to 90%)
±5%(< 10% or > 90%)
8
CO210-en-EU_V1.2 8/14
contact:
sale@ponpe.com