Extech Instruments CO210 User Manual

Extech Instruments CO210 User Manual

Co2 monitor and datalogger
Hide thumbs Also See for CO210:

Advertisement

Quick Links

User's Guide
CO
Monitor and Datalogger
2
Model CO210
GlobalTestSupply
www.
.com
Find Quality Products Online at:
sales@GlobalTestSupply.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CO210 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Extech Instruments CO210

  • Page 1 User's Guide Monitor and Datalogger Model CO210 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 2: Meter Description

    Introduction Congratulations on your purchase of this Model CO210 Carbon Dioxide Meter. This meter measures and datalogs CO level, air temperature, humidity, date and time. With visible and audible alarms, this is an ideal instrument for indoor air quality (IAQ) diagnosis. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service.
  • Page 3: Operation

    ESC button for 2 seconds again and it the meter returns to normal measurement mode. Minimum and Maximum recall continues working during logging. The memory is cleared whenever a new logging session is activated. CO210-en-EU_V1.2 8/14 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 4 100ppm increments. The alarm range is 700 to 1000ppm. When the value has been set, press the SET button to confirm the NORMAL limit and to proceed to for setting the upper POOR limit. Press the ESC button to exit without saving the setting. CO210-en-EU_V1.2 8/14 GlobalTestSupply www.
  • Page 5: Temperature Scale

    P3. or press the ESC button return to P3. without saving the setting. Repeat as above to finish the setting of P3. (Date), P3. (Hour) and P3. (Minute) CO210-en-EU_V1.2 8/14 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 6: Sampling Rate

    Press the SET button to save the setting and then repeat the procedure for P5. minutes and seconds Press the ESC button return to P5. without saving the setting. CO210-en-EU_V1.2 8/14 GlobalTestSupply www. .com Find Quality Products Online at:...
  • Page 7: Manual Calibration

    The Windows based pc software provided is used to set-up the datalogger, download data and to view the data in graphical or text format. After installing the software, view the HELP file for operational information. CO210-en-EU_V1.2 8/14 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 8: Maintenance

    -10 to 60°C (14 to 140°F); < 90% RH non-condensing Storage Conditions -20 to 60°C (-4 to 140°F); <99% RH non-condensing Power Supply 5VDC (±10%), 500mA (AC adaptor supplied) Dimensions / Weight 117x102x102mm (4.6x4x4”); 204g (7.2 oz.) CO210-en-EU_V1.2 8/14 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 9: Troubleshooting

    Refer to temperature error code for has error code problem solving The RH calibration has Please return for repair failed RH sensor or measuring Return for repair circuit has failed CO210-en-EU_V1.2 8/14 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 10: Co 2 Levels And Guidelines

    Germany, Japan, Australia, UK: 5000ppm, 8 hours weighted average occupational exposure limit is 5000ppm. Copyright © 2014 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form CO210-en-EU_V1.2 8/14 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...

Table of Contents