User's Guide Monitor and Datalogger Model CO210 contact: www.ponpe.com sale@ponpe.com...
Page 2
Introduction Congratulations on your purchase of this Model CO210 Carbon Dioxide Meter. This meter measures and datalogs CO level, air temperature, humidity, date and time. With visible and audible alarms, this is an ideal instrument for indoor air quality (IAQ) diagnosis. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service.
ESC button for 2 seconds again and it the meter returns to normal measurement mode. Minimum and Maximum recall continues working during logging. The memory is cleared whenever a new logging session is activated. CO210-en-EU_V1.2 8/14 contact: www.ponpe.com sale@ponpe.com...
Page 4
100ppm increments. The alarm range is 700 to 1000ppm. When the value has been set, press the SET button to confirm the NORMAL limit and to proceed to for setting the upper POOR limit. Press the ESC button to exit without saving the setting. CO210-en-EU_V1.2 8/14 contact: www.ponpe.com...
Page 5
LOG/▲ button or the MIN/MAX▼ button. Press the SET button to save the setting and then enter P3. or press the ESC button return to P3. without saving the setting. Repeat as above to finish the setting of P3. (Date), P3. (Hour) and P3. (Minute) CO210-en-EU_V1.2 8/14 contact: www.ponpe.com sale@ponpe.com...
Page 6
Press the SET button to save the setting and then repeat the procedure for P5. minutes and seconds Press the ESC button return to P5. without saving the setting. Year Month Date Year Month Date Hour Hour CO210-en-EU_V1.2 8/14 contact: www.ponpe.com sale@ponpe.com...
The Windows based pc software provided is used to set-up the datalogger, download data and to view the data in graphical or text format. After installing the software, view the HELP file for operational information. CO210-en-EU_V1.2 8/14 contact: www.ponpe.com sale@ponpe.com...
-10 to 60°C (14 to 140°F); < 90% RH non-condensing Storage Conditions -20 to 60°C (-4 to 140°F); <99% RH non-condensing Power Supply 5VDC (±10%), ≥ 500mA (AC adaptor supplied) Dimensions / Weight 117x102x102mm (4.6x4x4”); 204g (7.2 oz.) CO210-en-EU_V1.2 8/14 contact: www.ponpe.com sale@ponpe.com...
Page 9
Humidity Display Air temp. measurement Refer to temperature error code for has error code problem solving The RH calibration has Please return for repair failed RH sensor or measuring Return for repair circuit has failed CO210-en-EU_V1.2 8/14 contact: www.ponpe.com sale@ponpe.com...