Programming and Control, cont'd
www.camboard.de
5-4
IPL T PCS4 • SIS
CAMBOARD Electronics
Numbers can be entered as 1, 2, or 3 digits (e.g., 8V = 08V = 008V).
There are a few differences in how to enter the commands, depending on
whether you are using Telnet or a Web browser.
When using these commands through a Web browser, you can use the
o
URL reference to shorten the examples. "URL" refers to the full
address of the control interface and Web page reference, including all
path information (e.g., http://192.168.100.10/myform.htm).
To send any of the commands using a Web browser you must prefix
o
them with the full URL followed by ?cmd=.
For control via a Web browser, all non-alphanumeric characters must
o
be represented as the hexadecimal equivalent, %xx, where xx
represents the two-character hex byte. For example, a comma (,) would
be represented as %2C. Characters such as %, +, and the space
character must be encoded as hex bytes, or they will be misinterpreted
by the interface.
Some characters differ depending on the method you use to send the
o
commands:
Telnet
Escape (hex 1B)
Carriage return (hex 0D)
With Telnet you can use either an "Escape" command or a "W" command,
and the carriage return or the pipe character. With the Web browser, you are
required to use a "W" command and the pipe character.
In either method, {Data} = Data that will be directed to a specified port and
must be hex encoded if non-alphanumeric.
Tel. 07131 911201
Programming and Control
Fax 07131 911203
Web browser
W (must not be hex encoded)
|
Pipe character (
) (must not be hex
encoded)
ce-info@camboard.de