Front Panel Features and Operation, cont'd

Grouping receptacles

Two or more power receptacles can be grouped so that both their connected
devices can be controlled simultaneously. To group receptacles using the front
panel, follow these steps for each receptacle to be grouped.
1.
2.
3.

Ungrouping receptacles

To remove a receptacle from a grouping, follow these steps:
1.
2.
3.

Front panel security lockout (executive mode)

When the PCS4 is in executive mode, it does not accept commands from the front
panel. If any button is pressed while the unit is in executive mode, the Power
LED flashes three times, indicating that input from the front panel is not being
accepted.
To enter or exit executive mode, press and hold the Standby and Full buttons
simultaneously for 2 seconds. The Power LED flashes 3 times to indicate that the
mode has been switched.

Resetting the Unit

There are four ways to reset the PCS4 unit (called modes 1, 3, 4, and 5 for the sake
of comparison with other Extron IPL products). Reset the unit by pressing the
Reset button on the front panel (see Front Panel Features in chapter 3 for the button
location). This button is recessed; it can be accessed with a pointed stylus,
ballpoint pen, or an Extron Tweeker (a small screwdriver provided with the unit).
CAUTION
www.camboard.de
3-6
IPL T PCS4 • Front Panel Features and Operation
CAMBOARD Electronics
Place the receptacle in Configuration mode by pressing and holding its
receptacle button for two seconds. The green power LED (
continually, indicating that the unit is in Configuration mode.
Press each receptacle button repeatedly to cycle through the available group
selections, indicated by the LEDs beside the button, until you arrive at the
setting you want for the receptacle:
No LEDs lit — No groups (The receptacle will not be part of any
grouping.)
Yellow S LED lit — Group 1
Green F LED lit — Group 2
Red LED lit — Group 3
Press either the Standby or the Full button to exit Configuration mode.
Place the receptacle in Configuration mode by pressing and holding its
button for two seconds, until the green power LED (
Press the receptacle button repeatedly until none of its LEDs are lit
(indicating no groups).
Press the Standby or Full button to exit Configuration mode.
If power to the PCS4 is recycled while the unit is in executive mode, the
PCS4 remains in executive mode.
The reset modes described on the following pages break all TCP/IP
connections by closing all sockets to the unit.
Tel. 07131 911201
Fax 07131 911203
) flashes
1
) flashes continually.
1
ce-info@camboard.de