Error Response References; Using The Command/Response Table - Extron electronics IPL T PCS4 User Manual

Ip link power control interface
Hide thumbs Also See for IPL T PCS4:
Table of Contents

Advertisement

im Vertrieb von

Error response references

Using the Command/Response Table

www.camboard.de
CAMBOARD Electronics
The error response codes and their descriptions are as follows:
E12 – Invalid port number
E13 – Invalid value (the number is out of range/too large)
E14 – Not valid for this configuration
E17 – System timed out
E22 – Busy
E24 – Privilege violation
E25 – Device is not present
E26 – Maximum number of connections has been exceeded
E27 – Invalid event number
E28 – Bad filename or file not found
The following superscripted numbers are used within the command descriptions
on the following pages to identify commands that may respond as shown:
14
= commands that give an E14 (invalid command for this configuration)
response if sent to an IPL product whose power configuration does not
support the command.
24
= commands that give an E24 (privilege violation) response if you are not
logged in at the administrator level.
27
= commands that may yield an E27 (invalid event number) response.
28
= cmmands that may give an E28 (file not found) response.
The PCS4 can be controlled via either a Telnet (port 23) connection or a Web
browser (port 80) connection. The ASCII and URL commands listed in the tables
starting on page 5-7 perform the same functions, but they are encoded differently
to accomodate the requirements of each port (Telnet or browser).
The ASCII to hexadecimal (HEX) conversion table below is for use with the
command/response tables.
ASCII to HEX Conversion Table
ASCII to Hex conversion table
The command/response tables list valid ASCII (for Telnet) command codes, the
corresponding URL (universal resource locator) encoded (for Web browsers)
command codes, the interface's responses to the host, and a description of the
command's function or the results of executing the command.
Upper- and lower-case characters may be used interchangeably in the
command field unless otherwise specified.
Commands may be sent back-to-back without spaces (for example,
2!65V1Z).