None and Not Set thresholds

Clearing thresholds

www.camboard.de
CAMBOARD Electronics
9.
While holding down the Standby button, press and release the receptacle
button for the same device for which you set the Full threshold. The yellow
Standby LED for the selected receptacle blinks twice and remains lit.
1
F
Yellow
Standby
S
LED
Receptacle
10.
Release the Standby button.
11.
Repeat steps 1 through 9 for any other receptacles to which you have
connected devices to be controlled through the PCS4.
Settings that are made via the front panel for power output receptacles and
reference thresholds take approximately two minutes to be stored in memory.
If you recycle power too soon after settings have been made, the settings will
be lost.
These threshold settings are preserved if the PCS4's AC power is recycled or if
power is removed from an attached device. For example:
If the receptacle is set to Full and the power level drops below the stored
threshold, the receptacle's F (Full) LED shuts off, and the S (Standby) LED
lights.
If the receptacle is set to Standby and the power level drops below the
stored Standby threshold, the S LED shuts off.
If the receptacle is set to Standby and the power level exceeds the stored
Standby threshold, the F LED lights.
To indicate that the configuration has been saved, both the yellow Standby
LED and the green Full LED light and remain lit when those thresholds are
selected.
When a Full and/or Standby reference threshold has been set for a receptacle at
some time, and neither threshold is detected, a threshold status of None appears
on the Web page or can be the response to SIS
receptacle is powered off. The None threshold is a state that is detected; it cannot
be set manually.
If a receptacle has never been set to a Full or Standby reference threshold, its
threshold status is shown as Not Set on the Web page and in response to SIS
queries. Not Set is the default setting for reference thresholds.
To remove the reference threshold settings from any receptacle:
1.
Shut off power to the receptacle that you want to clear by pressing its button
on the front panel. The red LED to the right of the button shuts off.
2.
Press and hold the Standby or Full button while pressing and releasing the
receptacle button. All three receptacle LEDs flash twice, indicating that the
settings have been cleared.
3.
Release the Standby or Full button that you were holding.
If desired, you can now turn power for the receptacle on again by pressing
the receptacle's button.