Installation and Operation, cont'd
3 — Output sync format (RGBS or RGBHV)
On — The interface outputs RGBHV video (default).
Off — The interface outputs RGBS video.
4 — No Monitor at Power Up
On — The interface powers up with No Monitor enabled
(default).
Off — The interface powers up with No Monitor disabled.
5 — Auto Power
On — The interface powers up automatically when it
senses an input sync signal, and turns itself off
when the sync signal is removed.
Off — The interface does not power up or down
automatically; it stays on unless you remove power
by disconnecting the power cable.
6 — Not used

Pre-installation Testing and Troubleshooting

Before installing the interface into the wall or furniture, test the
system to verify that the connections and settings are correct.
Apply power to the interface. If an active sync signal is present
on the input or if the auto-power feature is disabled, the Power
LED on the interface lights to indicate that the interface is
receiving power.
If the LED does not light, check the wiring at both the interface
and the power supply, and ensure that the power supply is
connected to a power source.

If the image does not appear or there is no sound

1.
Make sure that all the devices are powered on.
Ensure that the connectors are wired correctly at both ends
2.
of the cables. Audio cables must be wired for an
unbalanced stereo input signal and for a balanced or an
unbalanced stereo output signal.
3.
If input is from a laptop computer and no picture appears,
check the computer's user's guide or contact Extron to
determine if special commands are required to output
video to the external video port. Also, many laptops'
screens shut off after the external video port is activated.
4.
Call the Extron S
3
the image still does not appear or there is no sound.
www.camboard.de
2-6
CIA111 and CIA114 • Installation and Operation
Sales and Technical Support Hotline if
CAMBOARD Electronics
Tel. 07131 911201
Fax 07131 911203

If the image is not displayed correctly

1.
Make sure the correct input and output cables are being
used and that they are not damaged.
2.
Check the DIP switch settings to make sure the interface is
putting out the correct sync format.
3.
If the picture appears and is stable, but it has ghosting or
blooming, verify that the video input is properly
terminated. If the problem is not resolved by changing the
termination, try using a different input cable. Poor quality
or damaged cable can cause ghosting or blooming.
4.
If the picture has a white, ghosted image on the right side
of the lines/characters, the sharpness may be set to high.
Use a Tweeker or screwdriver to turn the sharpness
control counterclockwise.
5.
If the picture still is not displayed correctly, call the Extron
S
3
Sales and Technical Support Hotline.
Once the system has been cabled and tested, the interface can be
installed in the wall or furniture. To mount the interface and
install optional MAAP devices (CIA111 only), see the next
section, Mounting the Interfaces.
Sound System
O R
N IT
M O
N O
IF T
E SH
A G
IM
U T
O U
TP
O R
N IT
M O
T
PU
R
IN
TE
M PU
C O
1
1 1
C IA
T
IN PU
D IO
A U
to
A u
e r
P ow
Presentation Monitor
Extron
CIA111
Computer Interface
Figure 2-5 — Typical CIA111 application
ce-info@camboard.de
CIA111 and CIA114 • Installation and Operation
LAN/WAN
Network/
Internet
Document
Camera
Local Monitor
PC
2-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cia114Cia114f5

Table of Contents