Keithley 2260B-30-72 User Manual page 72

2260b series, 360w and 720w multi-range programmable dc power supplies
Hide thumbs Also See for 2260B-30-72:
Table of Contents

Advertisement

Note
Master-Slave
Operation
2. For each unit, hold the Function
key while turning the power on to
enter the power on configuration
settings.
3. Configure F-93 (Master/Slave)
setting for each master/slave unit.
Unit
Master (local or series operation)
Slave unit (series)
4. Cycle the power on the units (reset the power).
Configuration settings can be checked for both the
master and slave units by pressing the Function
key.
Only operate the power supplies in series if the
units are configured correctly.
1. Turn on the master and slave unit. The slave
unit will only show the voltage of its own unit.
The master unit will show the combined
voltage of both units and the current.
Master unit
Slave unit
V
A
OPERATION
Page 96
F-93
0
4
V
69

Advertisement