Keithley 2260B-30-72 User Manual page 29

2260b series, 360w and 720w multi-range programmable dc power supplies
Hide thumbs Also See for 2260B-30-72:
Table of Contents

Advertisement

Reverse Current:
Regenerative load
Note
26
Current limit
level
Measured
Ammeter
current
When the power supply is connected to a
regenerative load such as a transformer or
inverter, reverse current will feed back to the
power supply. The 2260B power supply cannot
absorb reverse current. For loads that create
reverse current, connect a resistor in parallel to
the power supply to bypass the reverse
current. This description only applies when the
bleed resistance is off.
Power
Resistor
Supply
Reverse current
The current output will decrease by the amount of
current absorbed by the resistor.
Ensure the resistor used can withstand the power
capacity of the power supply/load.
2260B Series User Manual
Load

Advertisement

Table of Contents
loading

This manual is also suitable for:

2260b-30-362260b-80-132260b-80-27

Table of Contents