Remote monitoring
Voltage monitoring (VMON) and current
monitoring (IMON) are only supported on
the master unit.
The VMON voltage represents the total
voltage of the all the serialized units.
Remote Sense
Please see the remote sense chapter for
details, page 53.
External Voltage and Resistance Control
Voltage/Resistance controlled remote
control can only be used with the master
unit.
Slew Rate
The voltage slew rate is actually double that
of the setting slew rate. I.e., A voltage slew
rate setting of 60.00V/s is actually 120V/s
when in series.
Internal Resistance
Only the master unit's internal resistance
settings apply.
The internal resistance is actually twice that
of the setting value.
Bleeder Control
The Master unit is used to control the bleeder
settings. The bleeder resistor is always
turned on for the slave unit in series mode.
2260B Series User Manual