Grounding
The output terminals of the 2260B power supplies are isolated with
respect to the protective grounding terminal. The insulation
capacity of the load, the load cables and other connected devices
must be taken into consideration when connected to the protective
ground or when floating.
Floating
WARNING
28
As the output terminals are floating, the load
and all load cables must have an insulation
capacity that is greater than the isolation
voltage of the power supply.
Analog
connector
Ext-V
Ext-R
(
) Insulation capacity
of power supply
If the insulation capacity of the load and load
cables is not greater than the isolation voltage of
the power supply, electric shock may occur.
2260B Series User Manual
Power
Supply
isolation voltage