INSTALLATION

PRE-INSTALLATION
REQUIREMENTS
1. Provide approved electrical wiring to the power
supply. The 9060 power supply must be located
a minimum of 6.1m (20') outside of the hazardous
spray area.
2. Make sure the operating location has adequate
grounding facilities, such as electrical conduit,
steel building columns, metal water pipes, or other
earth grounded objects.
3. Furnish a paint pressure pot with air regulator (or
other accepted pressure system). The regulator
MUST have a reliable control, with a recommended
gauge range of 0-2.1 bar (0-30 psig).
4. Provide proper ventilation. (See "Safety" section
of this manual.)
5. Ensure that the target object to be coated
and all surrounding objects are grounded to a
known, earth ground by a separate ground wire
attachment.
C A U T I O N
!
† Do not use the power supply ground wire
to ground target objects. The targets objects
must have separate true earth ground for
best efficiency.

SAFEGUARDS

When operating this equipment in the vicinity
of computers, word processors, and/or other
electronic equipment, special care MUST be
taken to ensure that damage does not occur
from electrical energy discharges. (See Rans-
burg "Safety Literature" for further information
regarding application.)
AH-13-01.3
No. 2 Process Electric Motor Version - INSTALLATION
The following guidelines can be used:
It is highly recommended, whenever possible,
that ALL electronic components or equipment
be removed from the spray area. This includes
computer software such as tapes, disks, dis-
kettes, etc., located inside and/or around the
spray area.
If the static shielding of a unit is NOT KNOWN,
all electronic components (such as terminals,
screens, and cables) should be completely
wrapped in aluminum foil and grounded to a
true earth ground.
When painting electrical control panels or
consoles, wrap all push-buttons, switches,
meters, or pilot lights with aluminum foil and
ground to the panel or other earth ground.

EQUIPMENT INSTALLATION

!
† NEVER wrap the applicator, associated
valves and tubing, and supporting hardware
in plastic to keep it clean. A surface charge
may build up on the plastic surface and dis-
charge to the nearest grounded object. Effi-
ciency of the applicator will also be reduced
and damage or failure of the applicator's
components may occur.
† WRAPPING THESE COMPONENTS IN
PLASTIC WILL VOID WARRANTY