9060 Fuse Replacement - Ransburg 19372 Service Manual

No.2 process handgun electric motor version
Hide thumbs Also See for 19372:
Table of Contents

Advertisement

C A U T I O N
!
† DO NOT apply dielectric grease or any
other lubricant to the PTFE seal (Item 8), ce-
ramic seal (Item 5), drive shaft (Item 7), or
collar (Item 1). The application of dielectric
grease or any other lubricant to these com-
ponents can cause premature failure of the
motor.
10. Place the nut (Item 3) onto drive shaft (Item 7)
side with threads toward ceramic seal (Item 5).
Slide it back on drive shaft as far as it will go.
11. Slip the collar (Item 1) onto the drive shaft
(Item 7), align the two set screws with the two
flats in drive shaft. Secure the collar to the
drive shaft by tightening the two set screws
(Item 2).
12. Install the outer O-ring (Item 6) on the drive
shaft.
13. Install the resistor (black ink end first) and
spring into the rear of the drive shaft (Item 7).
Spring must be long enough to contact end
of resistor and motor shaft.
14. Holding the gun assembly with the front of the
barrel angled slightly downward, slide the drive
shaft (Item 7) into the front of the barrel until it
bottoms. Rotate the drive shaft by hand until
you feel the slot engage the motor shaft pin.
Tighten nut (Item 3) to secure the drive shaft
to the gun assembly.
C A U T I O N
!
† If the nut will not thread fully, the shaft is
not engaged. Unscrew and repeat Step 13.
AH-13-01.3
No. 2 Process Electric Motor Version - MAINTENANCE
† When ever the 9060 power supply is ser-
viced, insure that the power is off to the unit.

9060 FUSE REPLACEMENT

1. Insure the power is turned off on the front panel
switch. If possible disconnect the line cord to
the unit.
2. Insert a flat bladed screwdriver into the slot
of the fuse holder. Push the end of the fuse
holder in and turn counter-clock wise to remove
the fuse.
3. Inspect the fuse, insure it is the proper fuse
to give the proper protection. If faulty, replace
as required. Extra fuses are supplied with the
9060 and located inside the lid of the supply.
4. Insert the end of the fuse holder back with
the fuse in the center and push down while
turning the holder 1/4 turn clock-wise to lock
back in place.
W A R N I N G
!
Figure 25: Fuse Location