INSTALLATION

W A R N I N G
!
† Install and route the hoses and cable so
they are NOT exposed to temperatures in
°
excess of 120
are NOT LESS than a 6-inch (15 cm) radi-
us. Failure to comply with these guidelines
could cause equipment malfunctions that
might create HAZARDOUS CONDITIONS!
This information is intended ONLY to indicate
general installation guidelines of this product and
its working relationship to other Ransburg system
components. Each installation is unique and
should be directed by an Ransburg representative.

SAFE INSTALLATION

• Ground the spray booth, the paint supply, and
the conveyor or work support.
• Ground all solvent and waste safety containers.
• Ground all work holders and hooks and keep
them free of paint.
• Ground the target object to a structural ground
and not back to the applicator system. Ensure
that all target objects have a resistance to ground
of one megohm or LESS.
C A U T I O N
!
† Target grounding wire must not be con-
nected directly to the ground lug of the 9060.
A seperate ground line must be used for
each connection.
AH-07-01.10
F and so that all hose bends
Vector AA90 Applicators - Installation
• Ensure that all elements of the coating system
are correctly grounded, connected, and located.
• Position all non-approved electrical apparatus
(including, but not limited to, high voltage power
supplies, fluid pumps, and air compressors)
outside of the hazardous location. See the
appropriate country or local codes.
• Provide appropriate fire extinguishing equipment.
• Provide conductive flooring in all spray areas.
TYPICAL AA90 CASCADE
APPLICATOR
INSTALLATION
Connect the low voltage cable to the control unit low
voltage socket. Gently hand tighten the cable retaining
nut. Connect the other end of the low voltage cable
to the applicator, using a wrench to tighten. Slide the
cable boot over the nut.
C A U T I O N
!
DO NOT overtighten the low voltage
>
cable connection to the applicator. Dam-
age to plastic parts may occur.
The control unit may be connected through conduit
with an explosion-proof switch on or near the spray
booth where it will be convenient to the operator,
or may be connected with a power cord depending
upon application requirement.
18