Power Supply; Fluid Hose - Ransburg 19372 Service Manual

No.2 process handgun electric motor version
Hide thumbs Also See for 19372:
Table of Contents

Advertisement

Before attempting to install the equipment, ensure
that all the necessary components are available
(see "Parts Identification" section of this manu-
al). In addition, read all the technical and safety
literature that is provided. If the literature is not
available, contact your local Ransburg Distributor
where the equipment was purchased.
W A R N I N G
!
† The power source wiring and the power
supply connections to it MUST meet all local
fire and electrical code standards and com-
ply with all appropriate local and national
health and safety codes.
† All power supplies MUST be grounded
to a known true earth ground before any
other connections are made or functions
performed. DO NOT use the power supply
ground wire to ground the target objects (use
LSME4000-00 clamp assembly)!

POWER SUPPLY

(Refer to Figure 2)
1. The high voltage power supply MUST be located
at least 6.1 m (20 feet) from the spraying operation.
If a spray booth is used, the power supply may be
located 1.5 m (5 feet) from the nearest opening
and outside the booth .
2. If a line cord is used instead of a permanent
conduit connection, ensure the ground lead is
present on the plug. Ensure that the electrical
outlet is properly wired by using the circuit tes-
ter (20868-00). Attach the green ground wire to
a proven, true earth ground (i.e., water pipe or
electrical conduit).
3. After the power supply is grounded to a suit-
able earth ground, the high voltage cable may
be connected. Prior to connection of the high
voltage cable 15 to 30 ml of 3614-00 (supplied
with applicator ) di-electric oil needs to be added
to the power supply. Refer to figure 3 for illustra-
tion of where the oil should be inserted.
AH-13-01.3
No. 2 Process Electric Motor Version - INSTALLATION
4. Apply a generous amount of LSCH 0009 on
the power supply end of the cable as shown in
figure 3.
5. Attach the female nut of the high voltage ca-
ble to the male threads of the connection of the
power supply.
!
† Where the applicator is to be used with-
out a booth, the power supply must located
a minimum of 6.1 m (20 feet) from the target
being sprayed.
† The target Earth Ground and Power
Supply earth ground must be separate earth
ground connections.
† Any fluid hose that is are user supplied
must be rated for the maximum pressures
used for this applicator.

FLUID HOSE

(Refer to Figure 4)
Install the fluid filter (Item 5) to the applicator,
then to the fluid delivery hose. Attach one end
of the fluid hose to the adapter (Item 6) (Refer to
figure 4). This adapter has a 3/8-18 NPSM (F)
for attachment to a suitable fluid source. To meet
various length requirements, the hose fitting on
one end has not been attached.
Figure 5 illustrates the assembly procedure for
attaching the loose fitting.
W A R N I N G
10

Advertisement

Table of Contents
loading