FLEXLOGIC
Operand type
INPUTS/OUTPUTS:
Contact outputs,
current
(from detector on
form-A output only)
INPUTS/OUTPUTS:
Contact outputs,
voltage
(from detector on
form-A output only)
INPUTS/OUTPUTS:
Direct input
INPUTS/OUTPUTS:
RxGOOSE DPS
INPUTS/OUTPUTS:
RxGOOSE Booleans
5
INPUTS/OUTPUTS:
Virtual inputs
INPUTS/OUTPUTS:
Virtual outputs
LED INDICATORS:
Fixed front panel
LEDs
LED INDICATORS:
LED test
LED INDICATORS:
User-programmable
LEDs
5-174
Operand syntax
Cont Op 1
IOn
Cont Op 2
IOn
Cont Op 64
IOn
Cont Op 1 VOn
Cont Op 2
VOn
Cont Op 64
VOn
Cont Op 1
VOff
Cont Op 2
VOff
Cont Op 64
VOff
Direct I/P 1-1 On
Direct I/P 1-8 On
Direct I/P 2-1 On
Direct I/P 2-8 On
RxG DPS 1 BAD
RxG DPS 1 INTERM
RxG DPS 1 OFF
RxG DPS 1 ON
RxG DPS 2 to 5
RxG Bool 1 On
RxG Bool 2 On
RxG Bool 3 On
RxG Bool 256 On
Virt Ip 1 On
Virt Ip 2 On
Virt Ip 3 On
Virt Ip 64 On
Virt Op 1
On
Virt Op 2
On
Virt Op 3
On
Virt Op 96
On
LED IN SERVICE
LED TROUBLE
LED TEST MODE
LED TRIP
LED ALARM
LED PICKUP
LED VOLTAGE
LED CURRENT
LED FREQUENCY
LED OTHER
LED PHASE A
LED PHASE B
LED PHASE C
LED NEUTRAL/GROUND
LED TEST IN PROGRESS
LED USER 1
LED USER 2 to 48
Operand description
(does not appear unless ordered)
(does not appear unless ordered)
(does not appear unless ordered)
(does not appear unless ordered)
(does not appear unless ordered)
(does not appear unless ordered)
(does not appear unless ordered)
(does not appear unless ordered)
(does not appear unless ordered)
(appears only when an inter-relay communications card is used)
(appears only when inter-relay communications card is used)
(appears only when inter-relay communications card is used)
(appears only when inter-relay communications card is used)
Asserted while the RxGOOSE double-point status input is in the bad state
Asserted while the RxGOOSE double-point status input is in the intermediate
state
Asserted while the RxGOOSE double-point status input is off
Asserted while the RxGOOSE double-point status input is on
Same set of operands as per RxG DPS 1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Asserted when the front panel IN SERVICE LED is on
Asserted when the front panel TROUBLE LED is on
Asserted when the front panel TEST MODE LED is on
Asserted when the front panel TRIP LED is on
Asserted when the front panel ALARM LED is on
Asserted when the front panel PICKUP LED is on
Asserted when the front panel VOLTAGE LED is on
Asserted when the front panel CURRENT LED is on
Asserted when the front panel FREQUENCY LED is on
Asserted when the front panel OTHER LED is on
Asserted when the front panel PHASE A LED is on
Asserted when the front panel PHASE B LED is on
Asserted when the front panel PHASE C LED is on
Asserted when the front panel NEUTRAL/GROUND LED is on
An LED test has been initiated and has not finished
Asserted when user-programmable LED 1 is on
The operand above is available for user-programmable LEDs 2 through 48
L30 LINE CURRENT DIFFERENTIAL SYSTEM – INSTRUCTION MANUAL
CHAPTER 5: SETTINGS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents