GE L30 Instruction Manual page 197

Line current differential system
Hide thumbs Also See for L30:
Table of Contents

Advertisement

CHAPTER 5: SETTINGS
Table 5-3: RADIUS server settings
Setting name
Description
Primary RADIUS IP
IP address of the main RADIUS server.
Address
Default value indicates no Primary
RADIUS server is configured, and hence
RADIUS is disabled.
Primary
RADIUS authentication port
Authentication Port
Primary Accounting
RADIUS accounting port
Port
Vendor ID
An identifier that specifies RADIUS
vendor-specific attributes used with the
protocol
RADIUS
Authentication method used by RADIUS
Authentication
server. Currently fixed to EAP-TTLS.
Method
RADIUS
Shared secret used in authentication. It
Authentication
displays as asterisks. This setting must
(Shared) Secret
meet the CyberSentry password
requirements.
Timeout
Timeout in seconds between re-
transmission requests
Retries
Number of retries before giving up
Confirm RADIUS
Confirmation of the shared secret. The
Authentication
entry displays as asterisks.
(Shared) Secret
Table 5-4: General security settings
Setting name
Description
Session Lockout
Number of failed authentications before the
device blocks subsequent authentication
attempts for the lockout period
Session Lockout
The period in minutes that a user is prevented
Period
from logging in after being locked out
Syslog Server IP
The IP address of the target Syslog server to
Address
which all security events are transmitted
Syslog Server Port
The UDP port number of the target syslog
Number
server to which all security events are
transmitted
Device
When enabled, local Device authentication
Authentication
with roles is allowed. When disabled, the UR
only authenticates to the AAA server (RADIUS).
NOTE: Administrator and Supervisor (if still
enabled) remain active even after Device
authentication is disabled. The only permission
for local Administrator is to re-enable Device
authentication when Device authentication is
disabled. To re-enable Device authentication,
the Supervisor unlocks the device for setting
changes, and then the Administrator can re-
enable Device authentication.
L30 LINE CURRENT DIFFERENTIAL SYSTEM – INSTRUCTION MANUAL
Minimum
Maximum
0.0.0.0
223.255.255.254
1
65535
1
65535
EAP-TTLS
EAP-TTLS
See the
See the following
Password
password section
Requirements
for requirements
section earlier
in this chapter
0
9999
0
9999
See the
245 characters
Password
Requirements
section
Minimum
Maximum Default
0 (lockout
99
disabled)
0 (no period)
9999
0.0.0.0
223.255.
255.254
1
65535
Disabled
Enabled
PRODUCT SETUP
Default
Units
Minimum
permission
0.0.0.0
-
Administrator
1812
-
Administrator
1813
-
Administrator
Value that
Administrator
represents
General
Electric
EAP-TTLS
-
Administrator
N/A
-
Administrator
10
sec
Administrator
3
-
Administrator
N/A
-
Administrator
Units
Minimum
permission
3
-
Administrator
3
min
Administrator
0.0.0.0
-
Administrator
514
-
Administrator
Enabled
-
Administrator
5