6-3-3

Setting the Debug Log

Double-click DB Connection Service Settings under Configurations and Setup - Host
Connection Settings - DB Connection in the Multiview Explorer. Then, set the following in the
Service Setting.
Item
Number of files
File size
When the log is full
Delete the log at recording start
You can record a specified log as Debug Log using a DB_PutLog (Record Operation Log)
instruction. The logs recorded by a DB_PutLog (Record Operation Log) instruction are called
"user-specified log".
To record the user-specified log, set Log Type to Debug Log and specify the log code, log name,
and log message in a DB_PutLog (Record Operation Log) instruction and execute the instruction.
Refer to Appendix DB Connection Instructions for details of the DB_PutLog (Record Operation
Log) instruction.
NJ/NX-series Database Connection CPU Units User's Manual (W527)
6 How to Use Operation Logs
Description
Set the maximum number of files of
the Debug Log.
Set the maximum file size.
When the maximum file size is
exceeded or when the number of
records exceeds 65,536 records in
a file, a new file is created.
Set the action to be taken when the
Debug Log has reached the
maximum number of files.
Set whether to delete the Debug
Log contained in the SD Memory
Card when recording is started.
Values
1 to 100 files
(Default: 1)
1 to 100 MB
(Default: 10 MB)
- Stop logging (Default)
- Continue logging (Delete the
oldest file)
- Delete (Default)
- Do not delete