6-3-5

Stopping Recording to Debug Log

You can stop recording to the Debug Log by the following methods.
 Online operation from Sysmac Studio
 Executing a DB_ControlService (Control DB Connection Service) instruction
 Automatically stopped when a specified condition is met
Stop by Online Operation from Sysmac Studio
1
. Right-click DB Connection Service Settings under Configurations and Setup - Host
Connection Settings - DB Connection in the Multiview Explorer and select Online Settings
from the menu.
The following Online Settings Tab Page is displayed.
You can start and stop recording to the Debug Log by clicking the following buttons.
Category
Debug Log
2
. Click the Stop Button.
A confirmation message is displayed.
3
. Click the Yes Button.
Stop by executing a DB_ControlService Instruction
Specify Finish recording to Debug Log in the Cmd input variable of the DB_ControlService
(Control DB Connection Service) instruction and execute the instruction. Refer to Appendix DB
Connection Instructions for details of the instruction.
Automatically Stopped when a Condition is Met
The recording to Debug Log is automatically stopped in the following conditions.
 When the SD Memory Card power supply switch is pressed
 When the Synchronization (download) operation is executed on Sysmac Studio
 When the Clear All Memory operation is executed
 When the Restore operation of the SD Memory Card backup function or Sysmac Studio
Controller backup function is executed
NJ/NX-series Database Connection CPU Units User's Manual (W527)
Item
Button
Start/Stop
Start
Stop
6 How to Use Operation Logs
Operation
Recording to the Debug Log is started.
Recording to the Debug Log is stopped.