Omron NX701-17 Series Troubleshooting Manual page 100

Machine automation controller nj/nx-series
Hide thumbs Also See for NX701-17 Series:
Table of Contents

Advertisement

3 Error Tables
Event code
Event name
90150000 hex
Reset Exe-
cuted
90160000 hex
User Pro-
gram Execu-
tion ID Write
90180000 hex
All Controller
Errors
Cleared
90190000 hex
Forced
Refreshing
Cleared
901A0000 hex
Backup
(Ver. 1.03 or
Started
later)
901B0000 hex
Backup Com-
(Ver. 1.03 or
pleted
later)
901C 0000 hex
Restore
(Ver. 1.03 or
Operation
later)
Started
901D 0000 hex
Restore
(Ver. 1.03 or
Operation
later)
Completed
90200000 hex
SD Memory
(Ver. 1.11 or
Card Pro-
later)
gram Trans-
fer Started
90210000 hex
SD Memory
(Ver. 1.11 or
Card Pro-
later)
gram Trans-
fer
Completed
Errors Related to FINS Communications
The manual names are given below for the catalog numbers given in the Reference column of the
event table.
Cat. No.
W501
Event code
Event name
14010000 hex
CPU Bus
Unit Setup
Area Error
34100000 hex
IP Address
Table Setting
Error
3-22
Meaning
Assumed cause
A reset was exe-
• A reset command was
cuted.
received.
The user program
• A user with Administrator rights
execution ID was
changed the user program exe-
set or changed in
cution ID that is set in the CPU
the CPU Unit.
Unit.
All current errors
• The user cleared all current
were cleared.
errors.
Clearing a forced
• Clearing a forced refreshing
refreshing value
value was specified by the user.
was specified.
A backup operation
• A backup operation was
was started.
started.
The backup opera-
• The backup operation ended
tion ended nor-
normally.
mally.
A restore operation
• A restore operation started.
started.
The restore opera-
• The restore operation ended
tion ended nor-
normally.
mally.
Transferring the SD
• Transferring the SD Memory
Memory Card pro-
Card programs was started.
grams was started.
Transferring the SD
• Transferring the SD Memory
Memory Card pro-
Card programs was completed.
grams was com-
pleted.
NJ/NX-series CPU Unit Software User's Manual
Meaning
Assumed cause
An error was
• The power supply to the Con-
detected in the
troller was interrupted or com-
memory check of
munications with the Sysmac
the Setup Area for
Studio were disconnected while
CPU Bus Units.
downloading the CPU Bus Unit
Settings.
The IP address
• The IP address conversion
table settings are
method is set to the combined
incorrect.
method or the IP address table
method, but the IP address
table settings are incorrect.
Level
Maj
Prt
Min
Obs Info
Manual name
Level
Maj
Prt
Min
Obs Info
S
S
NJ/NX-series Troubleshooting Manual (W503)
Reference
S
W500, W501,
W535, W578
S
W500, W501,
W535, W578
S
W500, W501,
W535, W578
S
W500, W501,
W535, W578
S
W500, W501,
W535, W578
S
W500, W501,
W535, W578
S
W500, W501,
W535, W578
S
W500, W501,
W535, W578
S
W500, W501,
W535, W578
S
W500, W501,
W535, W578
Reference
W501
W501

Advertisement

Table of Contents
loading

Table of Contents