Step
Lubricate the caged o-ring. Carefully install the caged o-ring onto the valve from the straight end (opposite
17.
tapered end). Lubricate the grooves that the o-ring rides to fill in all void areas around the o-ring.
18.
Carefully install the valve with the caged o-ring in the dispensing valve body.
Install the spring fitting, knob and lever parts, torsion spring and spring housing assembly by reversing the
19.
removal procedure. Do not tighten down the hold-down plates securing the spring housing at this time.
After re-installing the faceplate, turn the dispensing valve spring housing to the left (counterclockwise) to put
tension on the tension spring. Apply just enough tension so that the dispense valve shaft returns to the
20.
closed position after release. Do not overtighten. Overtightening results in a high activation force on the
valve.
NOTE: Use Dow-Corning DC-111 (P/N 321471000) light grade silicone lubricant to lubricate the O-rings.

Sanitizing the System

The syrup systems should be sanitized every 180 days by a qualified service technician following the sanitizer
manufacturer's recommendations or when changing syrup types.
The sanitizing process consists of emptying the barrel, washing the lines and barrel, cleaning the BIB connectors,
rinsing and refilling the system.

Emptying a Barrel

To empty the barrel, perform the procedure in Table 38.
Step
1.
From the Barrel Status menu, press the DFRST button.
When the barrel is defrosted, go to the Maintenance menu. If the security feature is active, access the
2.
Maintenance menu by pressing and holding the far left and right buttons simultaneously for approximately
five seconds.
3.
Remove the splash panel. See "BRIX Setup Menu" on page 34.
4.
Turn the Product/BRIX valve 90 degrees clockwise to shutoff product to the barrel.
Place a large waste container under the dispense valve and drain as much product as possible from the
5.
barrel.
When the pressure in the barrel drops, from the Barrel Maintenance menu, press the PURGE button to
6.
repressurize the barrel with CO
spurting.
7.
Disconnect the BIB from the unit.
NOTE: The unit should be sanitized every 180 days by a qualified service technician following the sani-
tizer manufacturer's recommendations.

Flushing the System of Syrup

After emptying the barrel, the barrel should be flushed of product before proceeding with the sanitizing procedure.
Perform the procedure in Table 39.
© 2008-2015, Cornelius Inc.
Table 37.
Action
Table 38.
Action
As product level lowers in the barrel, partially close the valve to avoid
2.
- 47 -
Viper Service Manual
Publication Number: 621260373SER