Semi-Annual Maintenance; Inspecting And Replacing Scraper Blades - Cornelius Viper E 2 Flavor Service Manual

Hide thumbs Also See for Viper E 2 Flavor:
Table of Contents

Advertisement

Viper Service Manual
Step
1.
2.
3.
4.
5.
Tab
S
-A
M
EMI
NNUAL
AINTENANCE
There are several procedures that should be completed on a semi-annual basis. There procedures help to insure
proper operation of the system on a long term basis. Refer to Table 33. for a listing of the semi-annual mainte-
nance items.

Inspecting and Replacing Scraper Blades

Scraper blades should be inspected for wear during the semi-annual maintenance check. To inspect the blades,
perform the procedure in Table 35.
Step
1.
2.
3.
4.
5.
Publication Number: 621260373SER
Open the merchandiser
Remove the filter, shown in Figure 37, by grasping the two tabs and sliding it
straight out the front of the unit.
Wash the filter with clean water. Shake out the excess water.
Reinstall the air filter.
Close the merchandiser.
Figure 37. Air Filter Location
See "Purging a Barrel" on page 31.
When purging is complete, remove power from the unit.
Remove the four (4) 3/4 in. nuts from the faceplate and slowly remove the
faceplate from the unit.
Slowly pull the blade assembly out of the barrel.
Rinse and inspect the blade assembly for signs of wear.
Table 34.
Action
Table 35.
Action
- 44 -
Tab
© 2008-2015, Cornelius Inc.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Viper e 4 flavorViper e 3 flavor

Table of Contents