Prn Sub Regist - Konica Minolta magicolor 2590MF Service Manual

Hide thumbs Also See for magicolor 2590MF:
Table of Contents

Advertisement

Field Service Ver. 1.0 Aug. 2007
11.4.2

PRN SUB REGIST

Function
• To vary and adjust the print start position in the sub-scanning direction.
• If the image on the copy deviates in the sub scan direction
• When the PH unit has been replaced
Use
NOTE
• After the PRN MAIN REGIST adjustment has been performed
• Adjust the width of C in the printed test pattern1 so that the following specification is
met.
• 20 ± 2.5 mm
Adjustment
Specification
Adjustment
• -6.00 (-6.00 mm) ~ "0 (0 mm)" ~ +6.00 (+6.00 mm)
Range
• Step: 0.33 mm
1. Print the test pattern1.
See P.137
2. Check that the width of C in the test pattern1 meets the specification.
If the width of C is out of specification, adjust it according to the following procedure.
Setting/
3. Enter the [2. ADJUST] menu in the service mode.
Procedure
4. Select [PRN SUB REGIST] of [2. ADJUST] and press the Menu Select key twice.
5. Using the
6. Print a test pattern1 again and check it.
• If the width of C in the test pattern is longer than the specified width
Adjustment
..... Increase the setting.
Instructions
• If the width of C in the test pattern is shorter than the specified width
..... Decrease the setting.
C
/
key, change the setting value and then press the Menu Select key.
11. SERVICE MODE
4139F3C547DA
127

Advertisement

Table of Contents
loading

Table of Contents