Figure 1.10 Controller Leds; Table 1.4 Status And Meanings Of Each Led (Controller) - Fujitsu ETERNUS DX600 S3 Basic Operation Manual

Hide thumbs Also See for ETERNUS DX600 S3:
Table of Contents

Advertisement

Chapter 1
Component Name/LED Name
1.1
Controller Enclosures
Controller LEDs
Figure 1.10
shows the LEDs of the controller.

Figure 1.10 Controller LEDs

1
2
3 4
1.
READY LED
2.
FAULT LED
3.
LAN ACCESS LED
4.
LAN LINK LED
5.
MASTER LED
6.
IDENTIFY LED
7.
DI (OUT) FAULT LED
8.
DI (OUT) LINK LED
The LEDs turn on or blink to indicate the statuses that are listed below.

Table 1.4 Status and Meanings of Each LED (Controller)

LED name
READY
FAULT
LAN ACCESS
LAN LINK
MASTER
IDENTIFY
DI (OUT) FAULT
DI (OUT) LINK
FUJITSU Storage ETERNUS DX500 S3/DX600 S3 Disk storage system Operation Guide (Basic)
Table 1.4
5
6
7 8
LED status
(green)
(blinks green)
(amber)
(blinks amber)
(blinks green)
(green)
(green)
(blinks blue)
(amber)
(blinks amber)
(green)
20
Copyright 2014 FUJITSU LIMITED
shows the status and meanings of each LED.
7 8
Meanings
The controller is in normal status.
An error has occurred during startup.
The controller is in error status.
An error has occurred during startup.
Data is being sent or received via the LAN port (for operation
management).
The link between the LAN port (for operation management) and
the destination has been established.
The controller is set as a Master CM.
The installation location of the controller is identified according
to the instruction that is issued from ETERNUS Web GUI or ETER-
NUS CLI.
The link between the DI (OUT) port and the destination port is
in error status.
The ports to remove the mini SAS HD cables between enclo-
sures from are indicated. This occurs while a drive enclosure is
being added.
The ports to connect the cables are indicated. This occurs while a
drive enclosure is being added.
The link between the DI (OUT) port and the destination port has
been established.
P3AM-7742-04ENZ0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eternus dx500 s3

Table of Contents