3 . WARRANTY

We provide a limited warranty for our products. We will repair or replace the products if the cause of failure is due
to the following manufactures defects. Please contact us or your local distributor for details.
(1) Defect in manufacturing.
(2) Any shortage of components in the package.
(3) Where damaged components are found when initially opening the package.
(This shall not apply if the damage was caused by the negligence of a customer.)
4 . CONTACT US
For your safety and convenience when purchasing our products, we welcome your questions.
If you have any questions about operation, maintenance and repair of the product, please contact us.
Contact Us
Contact Us
For U.S. Market
Company Name
Business Hours
U.S. Toll Free No.
Telephone No.
Fax No.
Web Address
For Other Markets
Company Name
Business Hours
Telephone No.
e-mail Address
5 . FEATURES
① A high-speed brushless motor is used to achieve a maximum speed of
3080 J) and eliminate the need for motor brush maintenance.
② Speed control and protection functions utilize a high performance microprocessor.
③ Automatic control and monitoring of spindle functions are possible.
④ Wide speed range,
1 , 000 - 80 , 000 min
⑤ Compact CONTROLLER design allows easy installation in space restricted machines. Connectors and
control panel are front mounted for easy access.
⑥ The CONTROLLER is capable of being connected to AC
Sensing feature reduces installation time and elminates the possibility of connecting the wrong voltage.
⑦ Gear Mode Select Button is included. Set Gear Mode to display the rotating speed of the cutting tool when
using an angle spindle or speed reducer.
⑧ By setting the parameter
signal of the motor power line and the disconnect of the motor power line by safety relay, allows the E 3000
CONTROLLER to establish a safe spindle system.
⑨ By setting parameter
displayed. This allows Error Codes to be reviewed if no one is present when the error occurs. Error History
will be stored to the CONTROLLER, even if the Main Power Switch is turned OFF.
⑩ Since CONTROL will automatically recognize the motor attached and detect the maximum rotation speed,
there is no need to set maximum rotation speed based on types of motor.
:
Industrial Div.
: 8:30am to 17:00pm (CST)
(closed Saturday, Sunday and Public Holidays)
: 800-585-4675
: 847-843-7664
: 847-843-7622
: www.nskamericacorp.com
:
: 8:00am to 17:00pm
(closed Saturday, Sunday and Public Holidays)
: +81 (0) 289-64-3520
: webmaster-ie@nsk-nakanishi.co.jp
- 1
(rpm) makes high precision machining possible.
, Emergency Operating Function can be utilized. Using the open detection
, the CONTROLLER is capable of storing the last 5 Error Codes that were
- 1
80 , 000 min
(rpm) (when using EM-
100 V or AC 240 V power sources. The Auto