Selection of External Motor Start Signal Control Mode
Procedure
1 . Push the START / STOP Button (START / STOP)
2 .
is displayed. This indicates that motor startup and setting the rotation direction can not
performed simultaneously.
3 . Push the START / STOP Button (START / STOP)
4 .
is displayed. This setting is right hand rotation with motor startup by " Rotation Command (Pin
No. 14 : START) " or left hand rotation with motor startup by " Rotating Direction Setting (Pin No.
2 : DIR_IN) " can be set.
5 . You can cycle through the choices by pushing the START / STOP Button (START / STOP)
6 . Push the Error Reset Button (RESET)
7 .
If you desire to set other parameters, push the Motor Speed Adjustment Button (SPEED
to select the parameter that needs to be set.
8 . When you are nished setting parameters, press the Error Reset Button (RESET)
the Main Power Switch ⑨ is OFF.
Selection of Air input Monitoring Override
Procedure
1 . Push the START / STOP Button (START / STOP)
2 .
is displayed. This indicates that supplying cooling air into the motor spindle and motor speed
will perform normally at start - up.
3 . Push the START / STOP Button (START / STOP)
4 .
is displayed. This indicates that without supplying cooling air, motor startup is possible with
limited speed.
5 . You can cycle through the choices by pushing the START / STOP Button (START / STOP)
6 . Push the Error Reset Button (RESET)
7 .
If you desire to set other parameters, push the Motor Speed Adjustment Button (SPEED
to select the parameter that needs to be set.
8 . When you are nished setting parameters, press the Error Reset Button (RESET)
the Main Power Switch ⑨ is OFF.
Selection of Motor Speed Control Voltage / DC+ 10 V Signal Method
Procedure
1 . Push the START / STOP Button (START / STOP)
2 .
is displayed. This indicates that the motor characteristics will be maximum motor rotation
speed ( 60 , 000 min
3 . Push the START / STOP Button (START / STOP)
4 .
is displayed. This indicates that the motor characteristics will be maximum motor rotation
speed ( 80 , 000 min
5 . You can cycle through the choices by pushing the START / STOP Button (START / STOP)
6 . Push the Error Reset Button (RESET)
7 . If you desire to set other parameters, push the Motor Speed Adjustment Button (SPEED
⑬ to select the parameter that needs to be set.
8 . When you are nished setting parameters, press the Error Reset Button (RESET)
Main Power Switch ⑨ is OFF.
⑱ while displayed on
⑱ while displayed on
- 1
(rpm)).
- 1
(rpm)).
⑱ to send the settings to memory,
⑭ .
⑭ .
to store settings.
⑭ .
⑭ .
to store the setting.
⑭ .
⑭ .
⑭ .
,
) ⑬
⑱ , then turn
⑭ .
,
) ⑬
⑱ , then turn
⑭ .
will be displayed.
,
)
⑱ and turn the
91