When placing the CONTROLLER horizontally, the Rubber Pads (Provided) must be installed on the side
of the air vents. The Control Panel ② can be rotated 90 ° from the original position. To rotate, remove the 4
Control Panel Mounting Screw attached to Control Panel ② . Change position of the Control panel ② and re-
install the 4 Control Panel Mounting Screws.
Rubber Pad
Fig. 18
11 - 3 Proper Clearance
CAUTION
When installing 2 or more CONTROLLERs in the machine cabinet, make sure to check that each
unit has the proper clearance on all sides for suf cient air ow.
Insuf cient clearance will cause heat damage to the CONTROLLER and SELECTORS.
When installing the CONTROLLER and SELECTOR, refer to Fig. 20 and Fig. 21 .
min.30mm
Fig. 20 Vertical Mounting
Control Panel
Mounting Screw
Control Panel ②
min.20mm
min.30mm
Fig. 21 Horizontal Mounting
Fig. 19
min.20mm
63