Pin
Code
Function
No.
Torque Load
24
LOAD
Monitor
Rotating Speed
25
SPEED_V
Analog Monitor
Voltage
( 2 ) Input / Output Diagram
Connector A ③
(D-Sub25)
Connector B ④
(D-Sub15)
* 1 When using the " EMG - IN " Signal, set parameter
Stop Function " sectional.)
* 2 When using the " UD_IN and CNT_IN " Signal, set parameter
of External Speed Control Mode " section of the E 3000 CONTROLLER Operation Manual.)
72
Input /
Output
Torque Load Monitor
Output
(%) = Torque Load
Monitor Voltage x 20
- 1
Output 10 , 000 min
1
COM_1
(DC+24V or DC0V)
14
START
2
DIR_IN
4
RESET
16
500min
-1
(rpm)
17
SEL0
5
SEL1
15
UD_IN
*2
3
CNT_IN
*2
11
+10VDC
23
Potentionmeter
VR
5KΩ
10
GND
1
EMG-INA
*1
9
EMG-INB
*1
SAFETY RELAY CONTACT
Fig. 30
Description
Shows that the torque being applied to the
analog motor.
20 % / V 100 % (rating) / DC+ 5 V
Torque Load Monitor : 0 - 200 %
( 0 V ≦ LOAD ≦ 10 V)
Output the rotation speed of rotating motor
with Analog Monitor Voltage.
(rpm) / V
10 , 000 min
0 V
≦ SPEED_V ≦
GND
. (Refer to P 92 " 18 - 4 ⑨
. (Refer to P 90 " 18 - 4 ⑤
- 1
(rpm) / V
10 V
6
RUN
7
DIR_OUT
8
ERR
20
WARNING
21
COIN
19
PULSE
18
COM_2
(DC0V or DC+24V)
12
MOTOR_1
24
LOAD
25
SPEED_V
13
2
MT-CNA
10
MT-CNB
5
AUTO+
13
AUTO-
6
PWON+
14
PWON-
3
SAFE-1A
11
SAFE-1B
4
SAFE-2A
12
SAFE-2B
Selection of Emergency